Moving a Card
We can use LD 25 to move entire cards, shelves, or loops from one TN address to another. This is very useful if you need to move hardware around, perhaps to consolidate space as part of an upgrade.
Note: Use LD 25: MOV to move cards, shelves, or loops. Use LD 10/11/20: MOV to move individual sets.
Ground rules:
The following hardware may NOT be moved, and must be OUTed, and rebuilt:
- Consoles
- Digitone Receivers
- Dial Tone Detectors
- PRA loops
- ACD telephones
- NT8D17 Conf/TDS loops
In other words, use LD 25 to move analog/digital station cards, and analog trunk cards only.
Prompts and responses:
REQ MOV/SWP | - Move or swap TN data blocks, unit, shelf, and superloop data |
CUST <CR> * | - Moving superloop data on a customer basis is not supported * Enter a <CR> when moving or swapping superloop data |
SRC 1-50 | - Source Card for Small System |
DEST 1-50 | - Destination Card for Small System |
SRCL xxx | - Source Loop number from which data is to be moved |
DSTL xxx | - Loop number Destination to which data is to be moved |
SHCD ss TO ds | - Source shelf TO destination shelf |
SHCD ss c TO ds c | - Source shelf card TO destination shelf card |
SHSG ss sseg TO ds dseg | - Source Shelf Segment to destination Shelf Segment |
STSG 0-3 | - Starting destination Segment |
STUN xx | - Starting destination Unit Number |
Small System card move:
In the following example we will move slot 11 to slot 4, using LD 25:REQ mov move, or SWP to swap cards CUST leave customer blank! SRC 11 move source card number DEST 4 to destination card number FORCED DISCONNECT SOURCE FORCED DISCONNECT DESTINATION SCH5524 DN 3192 NEW MARP 004 0 00 00 SCH5524 DN 3174 NEW MARP 004 0 00 01 SCH5524 DN 3995 NEW MARP 004 0 00 02 SCH5524 DN 3971 NEW MARP 004 0 00 03 SCH5524 DN 3972 NEW MARP 004 0 00 04 SCH5524 DN 3996 NEW MARP 004 0 00 05 SCH5524 DN 3993 NEW MARP 004 0 00 06 SCH5524 DN 3273 NEW MARP 004 0 00 07 SCH5524 DN 3278 NEW MARP 004 0 00 08 SCH5524 DN 3142 NEW MARP 004 0 00 09 SCH5524 DN 3997 NEW MARP 004 0 00 10 SCH5524 DN 3124 NEW MARP 004 0 00 11 SCH5524 DN 3601 NEW MARP 004 0 00 12 SCH5524 DN 3103 NEW MARP 004 0 00 13 SCH5524 DN 3198 NEW MARP 004 0 00 14 SCH5524 DN 3178 NEW MARP 004 0 00 15 FORCED RE-CONNECT SOURCE FORCED RE-CONNECT DESTINATION
Large System (and CS1000) card move:
In the following example we move a COT card from 4 1 1 to 4 0 3:
REQ mov CUST leave customer blank! SRCL 4 source loop DSTL 4 destination loop SHCD 1 1 to 0 3 move shelf 1 card 1 to shelf 0 card 3 SHCD enter next card to move, or press return FORCED DISCONNECT SOURCE FORCED DISCONNECT DESTINATION FORCED RE-CONNECT SOURCE FORCED RE-CONNECT DESTINATION
In the following example we will move an ANLG card from 4 1 3 to 4 0 6:
REQ mov CUST leave customer blank! SRCL 4 source loop DSTL 4 destination loop SHCD 1 3 to 0 6 move shelf 1 card 3 to shelf 0 card 6 SHCD enter next card to move, or press return FORCED DISCONNECT SOURCE FORCED DISCONNECT DESTINATION SCH5524 DN 3606 NEW MARP 004 0 06 00 SCH5524 DN 3217 NEW MARP 004 0 06 01 SCH5524 DN 3242 NEW MARP 004 0 06 02 SCH5524 DN 3235 NEW MARP 004 0 06 03 SCH5524 DN 3200 NEW MARP 004 0 06 04 SCH5524 DN 3220 NEW MARP 004 0 06 05 SCH5524 DN 3218 NEW MARP 004 0 06 06 SCH5524 DN 3004 NEW MARP 004 0 06 08 SCH5524 DN 3607 NEW MARP 004 0 06 09 SCH5524 DN 3268 NEW MARP 004 0 06 10 SCH5524 DN 3266 NEW MARP 004 0 06 11 SCH5524 DN 3215 NEW MARP 004 0 06 12 SCH5524 DN 3216 NEW MARP 004 0 06 13 SCH5524 DN 3608 NEW MARP 004 0 06 14 SCH5524 DN 3609 NEW MARP 004 0 06 15 FORCED RE-CONNECT SOURCE FORCED RE-CONNECT DESTINATION