Mike's PBX Cookbook

Meridian 1 / SL1
General Maintenance Procedure

This is a general guideline for testing the complete system, adjust as necessary for the system you are working on.
Repair any faults found before going to the next command.

Network and Peripheral Equipment:

LoadCommandsNotes
LD 32STAT
LDIS loop shelf

List disabled units on shelf
LD 60STAT
SSCK x (0 - 1)
LCNT
Use LD 60 only if PRI/DTI is installed
If DTI is not installed, STAT the clock cards in LD 39
LD 96STAT DCHUse LD 96 only if PRI is installed
LD 39STAT IGS x (0 - 19)
STAT FIJI x y
STAT RING x (0 - 1)
STAT SCG x (0 - 1)
Use LD 39 only for SL1-XT or Options 71, 81 & 81C


If DTI is installed, STAT the clock cards in LD 60 only
LD 30LOOP ALLMemory test, continuity test, and signaling test on all XOPS cards
LD 45TESTComplete continuity test for one or all loops

CPU Maintenance:

OMEGA CPU SYSTEMSCORE SYSTEMS
LD 35STAT CMA x (0-1)
STAT MEM
STAT EXT
STAT CPU
CDSP
TCPU
SCPU
CDSP
CMAJ
CMIN ALL
LD 135STAT CNI
STAT CPU
STAT SUTIL
CDSP
TEST CPU
SCPU
CDSP
CMAJ
CMIN ALL
LD 37STAT TTYLD 137STAT
LD 37STAT TTY

Network connection matrix:

GroupShelfPer
Sig
3PE
Card
IGS 0
Card
IGM
Jack
IGS 1
Card
IGM
Jack
Loops
0000G00J12J60 - 15
0111G01J223J1716 - 31
1020G14J26J732 -47
1131G15J217J1648-63
2040G28J310J864 - 79
2151G29J2011J1580 - 95
3060G312J414J996 - 111
3171G313J1915J14112 - 127
4080G416J518J10128 - 143
4191G417J1819J13144 -159