Mike's PBX Cookbook

SCH5800 - 5899

SCH5803 CPU number out-of-range (0-1). 
SCH5804 The specified CNI port is in-service.
Action: Disable the CNI port before changing it. 
SCH5805 The specified group is configured for other CNI port. 
SCH5806 The specified slot is configured other than as CNI. 
SCH5807 Slot already exists for other card. 
SCH5808 Error occurred in printing CINV. 
SCH5809 TSA and ASA class of service are mutually exclusive.
SCH5810 Yellow alarm pattern of FDL can only be specified for ESF framing format. The software automatically enters YALM = DG2. 
SCH5812 Cannot delete DNCO, still in use. 
SCH5813 A USR key cannot be configured on a data set (CLS DTA). 
SCH5814 A set cannot have USR key with USRD Class of Service. 
SCH5815 Terminal’s Ringing Cycle Option (RCO) was reset from {old RCO} to default value 0, because the CLS was changed to FND and MWD. 
SCH5816 Warning: PBXT test scheduled for automatic execution in the daily routines 
SCH5817 CONF loops can only be defined on loops 29, 30 & 31 for Option 11. 
SCH5818 Cannot define CONF loop on loop 31 if only 1 cabinet defined. 
SCH5819 The VAS is in use in the customer data block under the VSID prompt.
Action: Delete the VAS from LD 15, then remove it from LD 17. To clear the VAS, use LD 15, and go to the VSID prompt. 
SCH5820 The VAS ID is in use by a CCR, Meridian Link, or Data application.
Action: Remove the VAS by using LD 23, then delete the VAS from LD 17. 
SCH5821 The VAS ID is in use by the teleset-messaging.
Action: Remove it in LD 23, then delete it from LD 17. 
SCH5822 The VAS ID is in use by the teleset-status.
Action: Remove it in LD 23, then delete it from LD 17. 
SCH5823 The VAS ID is in use by the CCR, or the Meridian Link application.
Action: Remove it in LD 23, then delete it from LD 17. 
SCH5824 The VAS does not exist.
Action: First create the VAS in the LD 17, then use it in LD 15. 
SCH5825 This loop cannot be removed until its associated DDSL has been removed first. 
SCH5826 Cannot change or print the Class of Service MREA/MRED in the TN block without the option enabled in LD 15.
Action: Enable NMDR/DMDR in LD 15 before attempting the change. 
SCH5827 Cannot assign a greater value to NMDR than to CFNA. Cannot assign a greater value to DMDR than to DFNA. Need to assign a value that is less than the value of CFNA or DFNA. 
SCH5828 ARP only authorized for CO Trunks. 
SCH5829 Maximum Dial Pulse time has to be greater than Minimum Dial Pulse time. 
SCH5830 You cannot delete, add, and change a loop at the same time. 
SCH5831 TSA not allowed while FTR = PHD. XFA prerequisite. 
SCH5832 BPO type not allowed for XEM. 
SCH5833 ARP only authorized for COT trunk. 
SCH5834 Maximum Dial Pulse Time has to be greater than the minimum Dial Pulse Time. 
SCH5835 Minimum Hook Flash Time has to be greater than the minimum Dial Pulse Time. 
SCH5836 Access code contains an invalid character. 
SCH5837 XPE package 203, SUPP package 131 or both packages are restricted. 
SCH5838 No predefined table or customized table has yet been built for B34 Static Loss Plan. This is a prerequisite for B34 Dynamic Loss Switching.
Action: Configure a table for B34 Static Loss Plan (TTYP = STAT) before configuring a table for B#$Dynamic Load Switching. 
SCH5839 Action: Contact system distributor to request the LAPW package; otherwise, log into the system using appropriate password which is authorized for changes to "configuration data", or contact system distributor to have this data updated. 
SCH5840 When entering a customized Static Loss Plan Table (Base Level Table) or a customized Dynamic Loss Plan Table (Alternative Level Table), {cr} will not be allowed if a table has not been previously installed.
Action: Enter all values for Rx and Tx or begin the command over and install a standard Predefined table, then customize a few values as required. 
SCH5841 Wrong number of parameters have been entered.
Action: Enter two values, one for Rx, and the second for Tx (or enter {cr} only) for all port types except RANR and PAGT. Enter one value for RANR (Rx) and PAGT (Tx), or enter {cr} only.
SCH5842 B34 Dynamic Loss Switching is disabled. B34 Codec Static Loss Downloading is now in effect.
Action: Enter two values, one for Rx, and the second for Tx (or enter {cr} only) for all port types except RANR and PAGT. Enter one value for RANR (Rx) and PAGT (Tx), or enter {cr} only.
SCH5843 The Table Number value entered is out-of-range.
Action: Enter a Table Number within the range, [1-25] for STYP, and [1-2] for DTYP.
SCH5844 The coded Relative Input/Output Level (Rx or Tx) value is out-of-range.
Action: Enter correct ranges as follows: Rx - (0 - 31)Tx - (8 - 39)
SCH5845 Cannot change number of AOMs because it deletes the BFS key.
Action: Remove BFS key first. 
SCH5846 You answered YES to the DITI prompt, but the DID to TIE package 176 is equipped. DID to TIE calls are restricted by the DID to TIE package. 
SCH5847 CNI slot 8, port 0 cannot be changed or deleted. 
SCH5848 The specified application is not configured on this MISP. 
SCH5849 BRI trunk types can only be TIE, COT, and DID. 
SCH5850 Cannot change these parameters without disabling all associated BRI trunk members. 
SCH5851 Interface type not valid for Basic Rate. This message indicates that the IFC trunk entered does not support Basic Rate trunks. 
SCH5852 Cannot out BRIL application without disabling the application. 
SCH5853 Cannot out BRIL application without outing all the associated DSLs. 
SCH5854 The specified route is not a BRI route. 
SCH5855 BRIT package is not equipped. 
SCH5856 The new MISP for this card does not have BRIL configured, but there is a BRIL DSL on this card. 
SCH5857 BRI route is not allowed if a BRI Route Packet Handler exists. 
SCH5858 PRI is not supported if the DTI2 package and the PRI2 package are not equipped. 
SCH5859 A DSL trunk in NT mode must be associated with a route on NET side. 
SCH5860 Protocol group cannot be removed. Remove the route(s) associated with this protocol and try again. 
SCH5861 Cannot out BRIT application without disabling the application.
SCH5862 Cannot out BRIT application without outing all the associated DSLs. 
SCH5863 The new MISP for this card does not have BRIT configured, but there is a BRIT DSL on this card. 
SCH5864 BRIL package is not equipped. 
SCH5865 ISDN option needs to be configured in the Customer Data Block before a BRI route can be configured. 
SCH5866 Either the BRIL or the BRIT package needs to be equipped. 
SCH5867 Line card is not a BRI SILC line card. 
SCH5868 {cr} is not allowed at TNUM prompt.
Action: Enter a Table Number within the range, [1-25] for STYP, and [1-2] for DTYP. 
SCH5869 Line card must be SILC for Numeris DSL. 
SCH5870 Warning: Another device is configured on the same card.
Action: Change the group number as well. 
SCH5871 Warning: There may be other devices on the QSDI card.
Action: Be sure the group number corresponds. 
SCH5872 NPID table does not exist. 
SCH5873 The NPID type cannot be entered because M911 package 224 is not equipped. 
SCH5874 NPID table already exists.
Action: Use CHG command. 
SCH5875 NPID table does not exist.
Action: Use NEW command. 
SCH5876 M911_NPID_MHPTR is Nil. 
SCH5877 NPID table out-of-range (0-7). 
SCH5878 All applications on the MSDL card are affected by the group number change. 
SCH5879 The Filter trigger entered is identical to an Exception trigger, or the Exception trigger entered is identical to a Filter trigger.
Action: Enter a different string or change the other Filter/Exception string. 
SCH5880 The mnemonic entered is invalid.
Action: Check and re-enter the desired mnemonic. 
SCH5881 The error code entered is invalid. Valid characters are 0-9 and + (plus sign).
Action: Check and re-enter a valid character. 
SCH5882 The SUPPRESS threshold cannot be less than the ESCALATE threshold.
Action: Check and re-enter the desired threshold.
SCH5889 Entered a number outside of the range allowed for the parameter for NEW and CPY commands in LD 18. The valid range is 1-100.
Action:Re-enter the NEW or CPY command with a new parameter between 1 and 100. 
SCH5890 Available memory is below the minimum allowed when trying to add multiple speed call lists at once using the NEW and CPY commands in LD 18. Minimum is 2048 words.
Action: Create the Speed Call lists one at a time, or free up additional memory. 
SCH5891 With X11 Release 19 and later, use one of the following formats for DN block printing:
1. multiple DNs may be printed by listing them at the DN prompt using commas to separate the individual DNs
2. a range of DNs may be entered using a dash between the starting and ending DNs 
SCH5892 Tried to disable B34 Static Loss Plan Download (SLPD) feature while B34 Dynamic Loss Switching (DLS) is still enabled. B34 SLPD not disabled.
Action: Disable B34 DLS before disabling B34 SLPD. 
SCH5893 BIMP value not apply to XUT. 
SCH5894 1200 OHM Termination impedance not apply to EXUT. 
SCH5895 Cannot select PSP/PIP without MR feature ON. 
SCH5896 DWC key’s DN does not match the ACD DN of the queue the agent is in. 
SCH5897 AWC key is already defined for this agent. 
SCH5898 DWC key is already defined for this agent. 
SCH5899 The appropriate DSL on this card (DSL #0 for PREF or DSL #1 for SREF) must be a trunk DSL.