SCH5700 - 5799
SCH5700 | Warning: Table 0 has been configured for this card by default. Verify Table 0 in LD 97 contains the desired parameters for dial tone detection. |
SCH5701 | XTD Table has not yet been defined in LD 97. |
SCH5702 | Tone and cadence table download already in progress. |
SCH5703 | Configure a DCH block for DPNSS in the LD 17 first. |
SCH5704 | A maximum of 16 characters are allowed for DES. |
SCH5705 | Input does not match the existing value of DES. Existing DES is not changed. Action: To remove a DES, enter "X" followed by the exact characters of the existing DES. |
SCH5706 | Input number of characters does not match the existing value of DES. Existing DES is
not changed. Action: To remove a DES, enter "X" followed by the exact characters of the existing DES. |
SCH5707 | DES value already exists. Action: To change a DES, you must remove the current DES first. To remove a DES, enter "X" followed by the exact characters of the existing DES. |
SCH5708 | This Primary Rate Interface B-channel is used for a connection between Basic Rate
Interface and a packet handler. Action: Remove the relationship in LD 27 first. |
SCH5710 | XSM is not allowed to be enabled for an active TTY. |
SCH5711 | Default XTD Table (Table 0) cannot be removed. |
SCH5712 | Table cannot be removed because it is configured for an XTD card. Action: Change XTD card configuration in LD 13 before removing Table. |
SCH5713 | Warning: Make sure that this XTD Table is not defined in any Route Data Blocks. |
SCH5716 | Warning: ARF is not allowed with BAT or LBS. Class of Service has been changed to ARF XBAT XLBS. |
SCH5717 | Warning: BAT is not allowed with ARF or LBS. Class of Service has been changed to BAT XARF XLBS. |
SCH5718 | Warning: LBS is not allowed with BAT or ARF. Class of Service has been changed to LBS XBAT XARF. |
SCH5719 | The XDID/EAM parameters may not be changed while the unit is busy. |
SCH5720 | Service loop (CONF, MFS, TDS, or XCT) cannot be added because the maximum number of service loops already exists. To add an XCT one of the TDS, MFS, or CONF loop service limits may be exceeded. In Release 14 the maximum number of service loops allowed is 15. In Release 17 the maximum number is 16. In Release 18 the maximum number is 64. |
SCH5725 | Invalid Controller number (out-of-range or undefined). |
SCH5726 | Cannot print an undefined Controller. |
SCH5727 | Cannot delete an undefined Controller. |
SCH5728 | Cannot delete a Controller that is not empty. Action: Remove TN assigned to superloops associated with this Controller first. |
SCH5729 | No free Controller available. |
SCH5730 | Location cannot have more than 6 characters. |
SCH5731 | Media must be COP (copper). |
SCH5735 | Remove all TNs assigned first. |
SCH5738 | Superloop number must be multiple of 4. |
SCH5739 | Cannot define that superloop. Some internal loops already exist as regular loops. Action: Remove all TNs and route numbers for the four loops higher than the new superloop. For example, to add superloop 4, old loops 4, 5, 6, and 7 must be undefined. |
SCH5740 | Cannot print a new superloop. |
SCH5741 | Cannot delete a new superloop. |
SCH5742 | Superloop number is out-of-range (0-255). |
SCH5743 | Cannot remove a superloop that is not empty. Action: Remove all TNs assigned to this superloop first. |
SCH5744 | Wrong number of input fields for the prompt SLOT. Action: Enter LEFT or RIGHT. |
SCH5745 | Invalid keyword for the prompt SLOT. |
SCH5746 | Cannot delete XPE0 for a new superloop. XPE0 does not exist. |
SCH5747 | Cannot remove undefined XPE0. |
SCH5748 | Cannot remove XPE0 that is not empty. Action: Remove all TNs assigned to this Controller. |
SCH5749 | Wrong number of inputs for the prompt XPE0. Action: Enter Controller number (0-95), starting segment (0-3), and ending segment (0-3). |
SCH5750 | Peripheral number is not defined or out-of-range. |
SCH5751 | XPE0 cannot have the same number as XPE1. Action: Remove XPE1 first. |
SCH5752 | Existing XPE0 is not empty. Action: Remove all information in order to change the Controller number. |
SCH5753 | Input segment number is out-of-range (0-3). |
SCH5754 | Another superloop already exists within the segments. |
SCH5755 | Starting segment number must be smaller than ending segment number. |
SCH5756 | Cannot remove segments that are not empty. Action: Remove all TNs assigned to this superloop. |
SCH5757 | {CR} is not allowed for the input. XPE0 has been deleted and XPE1 does not exist. |
SCH5758 | Define XPE0 or XPE1 for a superloop. |
SCH5759 | Cannot remove XPE1 from a new superloop. XPE1 does not exist. |
SCH5760 | Cannot remove undefined XPE1. |
SCH5761 | Cannot remove XPE1. XPE0 has been removed. Need information for XPE0 or XPE1. |
SCH5762 | Cannot remove XPE1. |
SCH5763 | Wrong number of input field for the prompt XPE1. Action: Enter Controller number (0-95), starting segment (0-3), and ending segment (0-3). |
SCH5764 | XPE1 cannot be the same as XPE0. |
SCH5765 | Existing XPE1 is not empty. Action: Remove all information in order to change the Controller number. |
SCH5767 | Input value is out-of-range. |
SCH5768 | Invalid input for prompt DTMF. |
SCH5769 | Invalid input for prompt P10P. |
SCH5770 | Invalid input for prompt S10P. |
SCH5771 | Invalid input for prompt 20PP. |
SCH5772 | Invalid input for INTN. Enter YES for A-law, NO for µ-law. |
SCH5773 | Allowed values for quiet code are 0-3. |
SCH5774 | Input out-of-range for maintenance thresholds, Allowed values are 1-65532. CONT is the number of continuity faults per timeslot and CRCF is the number of CRC failures per cable. |
SCH5775 | Input out-of-range for flash timer. FLSH can be 45-768 ms. |
SCH5779 | Both destination TNs must be unoccupied. |
SCH5780 | TN cannot be 0 0 0 0. |
SCH5781 | Card number for this superloop is invalid. |
SCH5782 | Cannot change card density for superloops. |
SCH5783 | SL-1 set cannot be located in a superloop. |
SCH5784 | Cannot move a pair when source TN is not a digital set. |
SCH5785 | Cannot move a pair when one of the TNs does not exist. |
SCH5786 | Superloop does not exist. |
SCH5787 | Invalid trunk for Universal Trunk or E & M Dictation Trunk. Conflict with one trunk type has already been defined. |
SCH5788 | 1200 Ohm termination impedance applies only to RAN trunks. |
SCH5789 | LST is not allowed for JCO in XTRK. |
SCH5790 | 1200 Ohm termination impedance should be used for RAN trunks in Universal Trunk. |
SCH5791 | 10PPS2 is for Universal Trunk or E & M Dictation Trunk only. |
SCH5792 | Code-a-Phone is not allowed on Controller RAN trunks. |
SCH5793 | Superloop number is not allowed for busy lamp field array. |
SCH5794 | Cards 10 to 14 are invalid for Network/DTR/XMFC Card array. |
SCH5795 | Shelf number is not defined for this superloop. |
SCH5796 | TN 0 0 0 0 is not allowed. Use this TN for DTR/XMFC. |
SCH5797 | TDET cannot be defined in a superloop. |
SCH5798 | Card density (DENS) must be defined.Action: Enter SDENS for single SDI ports (on CPU cards), DDEN for two port SDI cards (QPC139), QDEN for four port SDI cards (QPC841/NT8D41). |
SCH5799 | Superloop must be disabled before removing. |