Mike's PBX Cookbook

SCH5500 - 5599

SCH5500 Input value out of range 0-3.
SCH5501 There can only be one Wake Up Key (WUK) per set. Before moving the WUK key, the existing WUK must be removed (NUL). 
SCH5502 MAXT + DCMX cannot be greater than 255. 
SCH5503 Response to CTRQ must have 4 digits. 
SCH5504 First field of the response to CTAL cannot be longer than 16 digits. 
SCH5505 Second field of the response to CTAL is out-of-range (0-1023). 
SCH5506 Third field of the response to CTAL is out-of-range (0-4). 
SCH5507 ACD stations not allowed MCTA Class of Service unless the EMCT package is equipped. 
SCH5508 Same card and port number has been used. 
SCH5509 Warning! The entered DCH port may not be supported on your current Option 11 configuration.
Acceptable DCH port numbers are:
NTAK79 (PR12) card - one DCHI on port #1 is available
NTAK93 (PRI) card - one DCHI on port #1 is available
NTAK02 (DCHI/SDI) card - two DCHIs on ports #1 and #3 are available.
Action: If using one of the above cards, restart the overlay and enter an acceptable port number from the above list. If using other cards, proceed only after checking related documentation to confirm that the entered port number is acceptable. 
SCH5510 The keycodes entered for modifying the ISM parameters failed the security check 
SCH5511 The loop type is out-of-range or not supported. 
SCH5512 Warning: the DWC key is defined for a CDN which is not in controlled mode. DWC for a CDN in default mode is meaningless. 
SCH5514 This APL-TTY port is configured for the intercept computer feature. 
SCH5516 Incorrect response for RGTP. Enter 8 or 16. 
SCH5518 BGD package is restricted. 
SCH5519 Incorrect TYPE entered when REQ is CHG or PRT.
Action: Re-enter a correct type. 
SCH5522 The specified TN is not defined. 
SCH5523 A DST port type is not allowed when SAT = NO. 
SCH5524 DN xxxx NEW MARP l s c u The current TN is no longer the MARP TN for DN xxxx. The new MARP for DN xxxx has defaulted to TN l s c u. 
SCH5525 New TN(s) copied from a TN template with new DNs for the prime DN appearances. The new TNs are MARPs for the new prime DNs. Secondary DNs are copied without retaining MARP designations. 
SCH5526 Warning: In printing the DN block for a DN, no MARP or more than one MARP TN was found in the database. Only one MARP should be defined for a DN.
Action: Changing the database is recommended. 
SCH5527 X3W trunk requires DID trunk type. 
SCH5528 OHAS DN must be a Single Appearance, Multiple Appearance or ACD DN. 
SCH5530 The Set Relocation table does not exist; therefore, no operation may be performed on it. The Set Relocation package 53 may not be equipped. 
SCH5531 Exactly eight characters must be entered at prompt NTCD. 
SCH5532 Exactly six characters must be entered at prompt SER. 
SCH5533 Exactly two characters must be entered at prompt COLR and RLS. 
SCH5534 Input must be a valid hexadecimal digit (0-9, A-F). 
SCH5535 That TN cannot be found in the Set Relocation table.
Action: Print the relocation table to see the valid TNs. 
SCH5536 Autodial Timeout (ADLD) cannot be greater than dial tone interdigit timeout for 500 telephones (DIND) or 2500 telephones (DIDT). 
SCH5537 Invalid autodial DN. 
SCH5538 Invalid response to prompt PSEL.
Action: Enter DMDM or TLNK. 
SCH5539 Invalid response to prompt PSDS.
Action: Enter YES or NO. 
SCH5540 Invalid response to prompt V25.
Action: Enter YES or NO. 
SCH5541 Only OUT or CHG is allowed for TYPE = MTRT. 
SCH5542 TRAN must be SYN if PSDS = YES. Enter SYN to TRAN or set PSDS = NO before setting TRAN to ASYN. 
SCH5543 No customer or no customer with PREQ option set. 
SCH5544 Illegal key word. Should be R232 or R422. 
SCH5545 The group number must be input when a configuring a new device. No {cr} without input is allowed. 
SCH5546 Illegal key word. Should be DTE or DCE. 
SCH5547 Out of memory. Cannot allocate unprotected AML data store.
Action: To free some memory, deallocate I/O devices no longer in use, if they exist.
SCH5548 Out of memory. Cannot allocate protected AML data store.
Action: To free some memory, deallocate I/O devices no longer in use, if they exist. 
SCH5549 At least one user type must be defined. 
SCH5550 Out of memory. Cannot allocate required SDI memory.
Action: To free some memory, deallocate I/O devices no longer in use, if they exist.
SCH5551 The given user type is not allowed on the MSDL card (i.e., APL, HSL, LSL, are not allowed on MSDL card). 
SCH5552 Warning: To use the changed download parameters, must disable and enable the SDI port just modified. 
SCH5554 Invalid I/O progress marker detected.
SCH5555 Invalid input for ADAN prompt. 
SCH5556 Wrong action entered for ADAN prompt. 
SCH5557 Invalid device type for ADAN. 
SCH5558 Invalid device type for ADAN. 
SCH5559 AML cannot be configured due to package restriction. 
SCH5560 DCH cannot be configured due to package restriction. 
SCH5561 Invalid I/O device. 
SCH5562 No logical number entered for ADAN prompt. 
SCH5563 Invalid logical number or invalid I/O device. Example: OUT BDCH x to remove backup D-channel. 
SCH5564 Primary DCH must be specified. 
SCH5565 Backup DCH already configured for this primary DCH. 
SCH5566 No card type given. 
SCH5567 Invalid card type for TTY device. 
SCH5568 Invalid card type for AML device. 
SCH5569 Invalid card type for DCH device. 
SCH5570 Backup DCH must be on the same card type as primary DCH. 
SCH5571 No device number entered. 
SCH5572 No port number entered. 
SCH5573 Specified port not available, other ports are available. 
SCH5574 No port is available on the specified MSDL card. 
SCH5575 Invalid MSDL physical address. 
SCH5576 Invalid device number. Could conflict with already existing ADAN device number. 
SCH5577 Incorrect number of parameters for ADAN prompt. 
SCH5578 Logical application must be disabled. 
SCH5579 Physical I/O block pointer corruption. 
SCH5580 TTY cannot be configured. 
SCH5581 TTY cannot be changed. 
SCH5582 Disk cannot be configured. 
SCH5583 Disk cannot be changed.
SCH5584 TTY cannot be outed. 
SCH5585 TTY is still enabled. 
SCH5586 Device must be disabled to be outed. 
SCH5587 TTY error. 
SCH5589 Cannot out application from MSDL card, as this is the last application.
Action: Disable the MSDL card has to be disabled. 
SCH5590 The number of new logical applications (AML or DCH) has exceeded its allowable system limit. 
SCH5591 History File cannot be configured due to package restriction. 
SCH5592 History File cannot be configured due to no entry available in the I/O table. 
SCH5593 History File does not exist; therefore, cannot use the chg or del command. 
SCH5594 Data port out-of-range for MCU. Enter 8-15 on ISDLC cards, 16-31 on DAC cards. 
SCH5596 TRAN must be SYNC if PSDS = YES. 
SCH5597 BAUD must be 11 or 12 for PSDS = YES. 
SCH5598 Operating and system parameters may not be set properly for data option.
Action: Change PSEL or OPE if needed. 
SCH5599 Operating and system parameters may not be set properly for data option.
Action: Change PSEL or OPE if needed.