Network and Signaling Diagnostic
This program is used to maintain Network loops. It may be run in background, loaded during the daily routines, or loaded manually.
LD 30 is usually invoked as part of the Meridian 1 Daily Routines.
When invoked automatically by the system, the program performs the following tests:
- network memory of each enabled network card
- continuity of the speech path to each PE shelf (for enabled loops only)
- signaling channel to each line or trunk card (on enabled loops only)
- signaling channel through each ISDN line card
- clock controllers are switched.
Digital telephones that pass the signaling test have their date and time updated to match the system clock.
Any SL-1 telephone or card that fails the signaling test may be disabled by this program. Use LD 32 to re-enable them.
At typical LD 30 output (as part of the daily routines) is shown below:
DROL000 DAILY ROUTINE BEGIN NWS LD30 BEGIN 00:00 8/8/2001 NWS501 4 0 13 : -9 NWS501 4 0 14 : -11 NWS501 12 0 13 : -14 DROL001 DAILY ROUTINE END NWS LD30 END 00:00 8/8/2001
This printout shows that three TN's (Lscu) have failed the signaling test. As the unit numbers are preceeded by a minus sign, they have been disabled. The fault may be:
- PE card
- The telephone set
- Cabling (most probable!)
The units should be re-enabled in LD 32, and the cause of the fault investigated.
LD 32 NPR000 . ENLU 4 0 13 9
When invoked manually on systems other than the Option 11, the overlay may be used to:
- conduct a complete test, as when the program is invoked automatically, except for switching the clocks
- conduct a test on a specific PE shelf
- get the enable/disable status of network loops
- enable or disable network loops
- clear alarm conditions and the maintenance display
- download peripheral software on superloops
- clear the contents of the Controller maintenance display
- read the contents of the Controller maintenance display
When invoked manually on an Option 11 system, the program may be used to:
- conduct a complete test, as when the program is invoked automatically, except for switching the clocks
- clear alarm indications and the maintenance display
- perform a signaling test on a specific card or unit
- perform a continuity test and signaling test on the Option 11 XPE shelf
For further information, refer to the Software Input/Output Guide.