SCH5700 Warning: Table 0 has been configured for this card by default. Verify Table 0 in LD 97 contains the desired parameters for dial tone detection. 
SCH5701 XTD Table has not yet been defined in LD 97. 
SCH5702 Tone and cadence table download already in progress. 
SCH5703 Configure a DCH block for DPNSS in the LD 17 first. 
SCH5704 A maximum of 16 characters are allowed for DES. 
SCH5705 Input does not match the existing value of DES. Existing DES is not changed.
Action: To remove a DES, enter "X" followed by the exact characters of the existing DES. 
SCH5706 Input number of characters does not match the existing value of DES. Existing DES is not changed.
Action: To remove a DES, enter "X" followed by the exact characters of the existing DES. 
SCH5707 DES value already exists.
Action: To change a DES, you must remove the current DES first. To remove a DES, enter "X" followed by the exact characters of the existing DES. 
SCH5708 This Primary Rate Interface B-channel is used for a connection between Basic Rate Interface and a packet handler.
Action: Remove the relationship in LD 27 first. 
SCH5710 XSM is not allowed to be enabled for an active TTY. 
SCH5711 Default XTD Table (Table 0) cannot be removed. 
SCH5712 Table cannot be removed because it is configured for an XTD card.
Action: Change XTD card configuration in LD 13 before removing Table. 
SCH5713 Warning: Make sure that this XTD Table is not defined in any Route Data Blocks. 
SCH5716 Warning: ARF is not allowed with BAT or LBS. Class of Service has been changed to ARF XBAT XLBS. 
SCH5717 Warning: BAT is not allowed with ARF or LBS. Class of Service has been changed to BAT XARF XLBS. 
SCH5718 Warning: LBS is not allowed with BAT or ARF. Class of Service has been changed to LBS XBAT XARF. 
SCH5719 The XDID/EAM parameters may not be changed while the unit is busy. 
SCH5720 Service loop (CONF, MFS, TDS, or XCT) cannot be added because the maximum number of service loops already exists. To add an XCT one of the TDS, MFS, or CONF loop service limits may be exceeded. In Release 14 the maximum number of service loops allowed is 15. In Release 17 the maximum number is 16. In Release 18 the maximum number is 64. 
SCH5725 Invalid Controller number (out-of-range or undefined). 
SCH5726 Cannot print an undefined Controller. 
SCH5727 Cannot delete an undefined Controller. 
SCH5728 Cannot delete a Controller that is not empty.
Action: Remove TN assigned to superloops associated with this Controller first. 
SCH5729 No free Controller available. 
SCH5730 Location cannot have more than 6 characters. 
SCH5731 Media must be COP (copper). 
SCH5735 Remove all TNs assigned first. 
SCH5738 Superloop number must be multiple of 4. 
SCH5739 Cannot define that superloop. Some internal loops already exist as regular loops.
Action: Remove all TNs and route numbers for the four loops higher than the new superloop. For example, to add superloop 4, old loops 4, 5, 6, and 7 must be undefined.
SCH5740 Cannot print a new superloop. 
SCH5741 Cannot delete a new superloop.
SCH5742 Superloop number is out-of-range (0-255). 
SCH5743 Cannot remove a superloop that is not empty.
Action: Remove all TNs assigned to this superloop first. 
SCH5744 Wrong number of input fields for the prompt SLOT.
Action: Enter LEFT or RIGHT. 
SCH5745 Invalid keyword for the prompt SLOT. 
SCH5746 Cannot delete XPE0 for a new superloop. XPE0 does not exist. 
SCH5747 Cannot remove undefined XPE0. 
SCH5748 Cannot remove XPE0 that is not empty.
Action: Remove all TNs assigned to this Controller. 
SCH5749 Wrong number of inputs for the prompt XPE0.
Action: Enter Controller number (0-95), starting segment (0-3), and ending segment (0-3).
SCH5750 Peripheral number is not defined or out-of-range. 
SCH5751 XPE0 cannot have the same number as XPE1.
Action: Remove XPE1 first. 
SCH5752 Existing XPE0 is not empty.
Action: Remove all information in order to change the Controller number. 
SCH5753 Input segment number is out-of-range (0-3). 
SCH5754 Another superloop already exists within the segments.
SCH5755 Starting segment number must be smaller than ending segment number. 
SCH5756 Cannot remove segments that are not empty.
Action: Remove all TNs assigned to this superloop. 
SCH5757 {CR} is not allowed for the input. XPE0 has been deleted and XPE1 does not exist.
SCH5758 Define XPE0 or XPE1 for a superloop. 
SCH5759 Cannot remove XPE1 from a new superloop. XPE1 does not exist. 
SCH5760 Cannot remove undefined XPE1. 
SCH5761 Cannot remove XPE1. XPE0 has been removed. Need information for XPE0 or XPE1.
SCH5762 Cannot remove XPE1. 
SCH5763 Wrong number of input field for the prompt XPE1.
Action: Enter Controller number (0-95), starting segment (0-3), and ending segment (0-3).
SCH5764 XPE1 cannot be the same as XPE0. 
SCH5765 Existing XPE1 is not empty.
Action: Remove all information in order to change the Controller number. 
SCH5767 Input value is out-of-range. 
SCH5768 Invalid input for prompt DTMF. 
SCH5769 Invalid input for prompt P10P. 
SCH5770 Invalid input for prompt S10P. 
SCH5771 Invalid input for prompt 20PP. 
SCH5772 Invalid input for INTN. Enter YES for A-law, NO for µ-law. 
SCH5773 Allowed values for quiet code are 0-3. 
SCH5774 Input out-of-range for maintenance thresholds, Allowed values are 1-65532. CONT is the number of continuity faults per timeslot and CRCF is the number of CRC failures per cable. 
SCH5775 Input out-of-range for flash timer. FLSH can be 45-768 ms. 
SCH5779 Both destination TNs must be unoccupied. 
SCH5780 TN cannot be 0 0 0 0. 
SCH5781 Card number for this superloop is invalid. 
SCH5782 Cannot change card density for superloops. 
SCH5783 SL-1 set cannot be located in a superloop. 
SCH5784 Cannot move a pair when source TN is not a digital set. 
SCH5785 Cannot move a pair when one of the TNs does not exist. 
SCH5786 Superloop does not exist. 
SCH5787 Invalid trunk for Universal Trunk or E & M Dictation Trunk. Conflict with one trunk type has already been defined. 
SCH5788 1200 Ohm termination impedance applies only to RAN trunks. 
SCH5789 LST is not allowed for JCO in XTRK. 
SCH5790 1200 Ohm termination impedance should be used for RAN trunks in Universal Trunk.
SCH5791 10PPS2 is for Universal Trunk or E & M Dictation Trunk only. 
SCH5792 Code-a-Phone is not allowed on Controller RAN trunks. 
SCH5793 Superloop number is not allowed for busy lamp field array. 
SCH5794 Cards 10 to 14 are invalid for Network/DTR/XMFC Card array. 
SCH5795 Shelf number is not defined for this superloop. 
SCH5796 TN 0 0 0 0 is not allowed. Use this TN for DTR/XMFC. 
SCH5797 TDET cannot be defined in a superloop. 
SCH5798 Card density (DENS) must be defined.Action: Enter SDENS for single SDI ports (on CPU cards), DDEN for two port SDI cards (QPC139), QDEN for four port SDI cards (QPC841/NT8D41). 
SCH5799 Superloop must be disabled before removing.