Mike's PBX Cookbook

SCH3500 - 3599

SCH3500 ATM package not equipped on this system. 
SCH3501 ATM data block already exists. 
SCH3502 ATM data block does not exist. 
SCH3503 This route TYPE is 3515 not allowed for ATM testing. 
SCH3504 Cannot out ATM, route still scheduled for ATM. 
SCH3505 Number of DN digits exceeds 10. 
SCH3506 ATM DN must be two or more digits long. 
SCH3507 PAD value out-of-range. 
SCH3508 LOSS value out-of-range.
SCH3509 NOISE limit out-of-range. 
SCH3510 PERCENT out-of-range. 
SCH3511 ATM SCHEDULE block does not exist. 
SCH3512 ATM SCHEDULE block already exists. 
SCH3513 Customer has no SCH data for this hour, use NEW to create SCH data for this customer. 
SCH3514 Customer already has SCH data for this hour.
Action: Use CHG to change SCH data or OUT to delete customer’s SCH data from given hour. 
SCH3515 Cannot OUT RDB; ATM data still associated with RDB. 
SCH3516 Hour for SCH data is out-of-range. 
SCH3517 Out of service limit is less than maintenance limit. 
SCH3518 MXTI value is out-of-range. 
SCH3519 DN Digit out-of-range. 
SCH3520 ATM cannot be performed on this route because FEDC is equal to FEC. 
SCH3521 SCI package is not provided. 
SCH3522 CCOS package is not implemented. 
SCH3523 DN specified is not BCS or PBX DN. 
SCH3524 Invalid CCOS restriction level. 
SCH3525 SCH data is deleted during memory transfers. 
SCH3526 This route has not been scheduled for ATM test. 
SCH3527 This route has already been scheduled for ATM test. 
SCH3528 ATM Schedule data does not exist for this hour. 
SCH3530 Pad Value must be input (0-63 dB). 
SCH3531 DN must be input. 
SCH3532 Loss value must be input (0-15 dB). 
SCH3533 Noise value must be input (27-90 dBrn). 
SCH3534 lll ch, B-channel ch of loop lll can be removed when it is idle. ISL channels need to be idled also. 
SCH3545 Threshold set is already deleted. 
SCH3546 Cannot remove TSET until all DTI/DLIs assigned to it are removed. 
SCH3547 The VAS ID of a data service access code that is defined as the primary access code for a data service DN may not be changed. 
SCH3548 If Class of Service is VMA, class must also be VCE. 
SCH3549 Server cannot remove access code. It still has agents defined. 
SCH3550 VAS Server (PTE) cannot add the access TN because it already exists in the Server (PTE) data base. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try either: 1. removing the TN and adding it back in, or 2. running Audit. 
SCH3551 VAS Server (PTE) cannot remove the access TN because the access TN does not exist in the Server (PTE) data base. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try either: 1. adding the TN and then removing it, or 2. running Audit. 
SCH3552 VAS Server (PTE) cannot add the access code because it already exists in the Server (PTE) data base. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try either: 1. removing the DN and adding it back in, or 2. running Audit. 
SCH3553 VAS Server (PTE) cannot remove the access code because it does not exist in the Server (PTE) data base. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try running Audit.
SCH3554 Server cannot add/remove the voice/data access code because it is a data/voice access code.
SCH3555 VAS Server (PTE) cannot remove the access TN because it is not in the Server (PTE) list of TNs belonging to the specified access code. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try either: 1. adding the TN back in and then removing it, or 2. running Audit. 
SCH3556 VAS Server (PTE) cannot add the access code (if in LD 23) or the access TN (if in LD 11) because the disk save failed. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try either: 1. removing the TN (if in LD 11) or DN (if in LD 23) (OUT) and adding it back in (NEW), or 2. running Audit.
SCH3557 VAS Server (PTE) cannot remove the access code (if in LD 23) or the access TN (if in LD 11) because the disk delete failed. This could mean that the data bases do not match.
Action: To ensure compatibility of the shared data bases (when the CSL link is up), try either: 1. adding the TN back in (if in LD 11) or DN (if in LD 23) (OUT) and then removing it (NEW), or 2. running Audit. 
SCH3558 SCD DB LD 73 - No DTI threshold set defined. 
SCH3559 TRSH may not be defaulted when configuring a new digital loop. 
SCH3560 The threshold set is not defined. 
SCH3561 If Class of Service is VMA, class must also be IMA. 
SCH3562 If Class of Service is IMA, class must also be VCE. 
SCH3566 The VMS option (CMS, IMA and IVMS = YES) may not be removed if agents are still defined for this DN. 
SCH3567 An existing ACD DN may not be set up as a VMS access code (CMS, IMA, and IVMS = YES) if agents are still defined for that DN. 
SCH3568 The TN defined as the SADM TN for the indirect CSL (CLS = CMSA) must be a normal SL-1 set TN (i.e., it cannot be a digital set or a virtual TN; e.g. TYPE cannot be 4020, CLS = DSI or VMA) 
SCH3570 The VAS ID of the Server (PTE) for which the access code is defined (VSID prompt for either the data service or VMS access code in LD 23) must match the VAS ID of the Server (PTE) for which the access TN is defined (i.e., the VAS Server (PTE) for which the DLI loop is defined — DLOP under the VAS prompt in LD 17). 
SCH3571 The TN defined as the SADM TN for the indirect CSL (CLS = CMSA), must not be a virtual TN on a DLI loop. 
SCH3572 IMA may not be turned off if the CSL option is set (CMS = YES) and there are agents defined for this ACD DN. This is because agents require a special Class of Service for IMA. 
SCH3574 If a DLI loop is specified, then TYPE must be TNB (for LUU). 
SCH3575 Invalid CONFIRM return code. 
SCH3576 The server has software error. Cannot complete the service change. 
SCH3577 The server has data base error. Cannot complete the service change. 
SCH3579 OPR trunk members not on private line routes, must have DTN COS. 
SCH3580 To be OPR allowed, all members must have DTN COS. 
SCH3581 ICDR package required. 
SCH3582 SLP package not equipped. 
SCH3583 PRMA requires WTA COS. 
SCH3584 PHTA requires HTA COS. 
SCH3585 PHTA/PCWA require PRMA COS. 
SCH3586 Invalid CPAS DN. 
SCH3587 MCT package not equipped. 
SCH3588 ACD stations not allowed MCTA COS with X11 Release 18 and earlier. 
SCH3589 TRC key is not allowed when telephone is MCTD. 
SCH3590 LLC package not equipped. 
SCH3591 Only digits 0-9 considered as valid input for the digit count field. 
SCH3592 XFA required for MCTA. 
SCH3593 OVFL not allowed for PFAN/PFNA. 
SCH3594 PRMA not allowed on ACD sets. 
SCH3595 PCWA COS requires Call Waiting (CWT) key. 
SCH3596 This list number was not assigned to this PBX set. 
SCH3597 Cannot move an ACD DN with calls store in the queue.