Option 11 E&M Trunk Card
Configuration Example
Introduction
The following configuration example will show you how to configure the Nortel PBX Option 11 E&M Trunk Card. This configuration will allow you to connect this card to a Cisco E&M voice port.
Hardware and Software Versions
To implement this configuration, you need the following:
- Nortel PBX software uses Release 23 or later
- Nortel PBX Option 11 Model.
Configuration
In the following configuration, notes about the configuration are in bold italics. The <RET> throughout the cofiguration indicates that you need to hit the return key after the respective command parameter.
#ADDING E&M CARD: (BUILDING ROUTE DATA BLOCK. USE DOUBLE DIGITS W/ ROUTE DATA BLOCK.) LD16(LOAD 16) REQ:NEW TYPE:RDB CUST:0 DMOD:<RET> ROUT:21 TKTP:TIE ESN:<RET> (ALL RETURNS UNTIL ICOG PROMPT) ICOG:IAO (INCOMING, OUTGOING) SRCH:<RET> TRMB:<RET> STEP:<RET> ACOD:71 TARG:0 (TGAR 0 AND ENDCOST 0) BILN:<RET> (ALL RETURNS UNTIL CNTL PROMPT) CNTL:YES TIMR:<RET> SST:<RET> NEDC:ETH(NEAR END DISCONNECT SET FOR EITHER) FEDC:ETH(FAR END DISCONNECT SET FOR EITHER) CPDC:<RET> (ALL RETURNS UNTIL ALRM) <SHIFT>**** LD21(LOAD 21 TO VIEW RDB) REQ:PRT TYPE:RDB CUST:0 ROUT:21 <SHIFT>******** (IF YOU NEED TO CHANGE FROM 2 WIRE TO 4 WIRE CABLES OR VICE VERSA, ALSO CHANGE IN PBX CONFIG) LD14(LOAD 14 TO ADD NEW TRUNK) REQ:NEW TYPE:TIE TN:9 0(ANALOG STARTS AT 0 DIGITAL STARTS AT 1) XTRK:XEM CUST:0 NCOS:0 RTMB:21 1 MNDN:<RET> TGAR:0 SIGL<RET> EMTY:TY1(DEPENDS ON CABLING) CPAD:<RET> STRI:IMM STR0:IMM SUPN:<RET> CLS:UNR DTN(CLASS OF SERVICE) TKID:<RET> <SHIFT>******** VIEW TRUNK. LD20(LOAD 20) REQ: PRT TYPE: TRK TN: 9 0 RTMB: (All returns until the end) <SHIFT>******** AFTER FINISHING ALL 4 TRUNKS YOU MUST ENABLE THE TRUNKS. LD32 STAT 9 DISC 9(DISABLE CARD 9:THE E&M CARD) ENLC 9(ENABLE CARD 9) <SHIFT>******** TO MODIFY E&M TYPE, OPERATION(2 OR 4-WIRES) AND SIGNALLING. LD14(LOAD 14 TO ADD NEW TRUNK) REQ:CHG TYPE:TIE TN:9 0(ANALOG STARTS AT 0 DIGITAL STARTS AT 1) XTRK:XEM CUST:0 NCOS:0 RTMB:21 1 MNDN:<RET> TGAR:0 SIGL<EM4> (EM4 FOR 4-WIRES, EAM FOR 2-WIRES) EMTY:TY2 (E&M TYPE 2 DEPENDS ON CABLING) CPAD:<RET> STRI:WNK STR0:WNK SUPN:<RET> CLS:UNR DTN(CLASS OF SERVICE) TKID:<RET> <SHIFT>********