Digital Station Module DIP Settings

The DSM 16 supports 16 Nortel handsets. It requires a DS30 bus to function and 1 bay on the BCM CCU.
The DSM 32 supports 32 Nortel handsets. It requires one DS30 bus to function and 1 bay on the BCM CCU.
Both modules support the M series handsets and the new T series handsets


Note: BCM50/450: Module DIPs are set to the default - ALL "ON"- position, and must
be must be assigned to a pseudeo slot number in Resources > Telephony Resources.


DSM 16+
bcm_dsm16.jpg (4225 bytes)

DSM 32+
bcm_dsm32.jpg (4754 bytes)

Bus DIP Switch Settings DN
Assignment
1 2 3 4 5 6
2 off on on on on on 221 - 236
off on off on on on 237 - 252
3 off on on on on off 253 - 268
off on off on on off 269 - 284
4 off on on on off on 285 - 300
off on off on off on 301 - 316
5 off on on on off off 317 - 332
off on off on off off 333 - 348
6 off on on off on on 349 - 364
off on off off on on 365 - 380
7 off on on off on off 381 - 396
off on off off on off 397 - 412
Bus DIP Switch Settings DN
Assignment
1 2 3 4 5 6
2 off on on on on on 221 - 236
            237 - 252
3 off on on on on off 253 - 268
            269 - 284
4 off on on on off on 285 - 300
            301 - 316
5 off on on on off off 317 - 332
            333 - 348
6 off on on off on on 349 - 364
            365 - 380
7 off on on off on off 381 - 396
            397 - 412

After you set the DIP switches on a media bay module, you can install it in the BCM or an expansion unit - all bay slots are the same.

When adding a module, remember to tell the system what type of module is installed on each bus:

If a module status LED continues to flash, you have either an addressing conflict (check DIP switches), or a faulty module.

Remember, the BCM must be shut down before inserting or removing modules.